The S5735-S48S4XE-V2 is an advanced enterprise-grade switch designed for high-performance campus networks, delivering enhanced forwarding capabilities, flexible uplink options, and robust security features. Built to support digital transformation in organizations, it provides scalable connectivity for enterprises, education networks, and service providers requiring reliable and efficient data exchange.
The S5735-S48S4XE-V2 belongs to a next-generation Ethernet switching portfolio that focuses on stability, flexibility, and high bandwidth performance. It is engineered to handle large-scale access aggregation while maintaining low latency and high reliability. With strong hardware design and intelligent traffic management, it supports evolving network demands in modern IT environments.
This model is widely used in campus aggregation layers where multiple access switches converge. Its architecture ensures seamless communication between endpoints, cloud services, and data centers, making it a crucial component of enterprise digital infrastructure.
The S5735-S48S4XE-V2 delivers a combination of hardware strength and intelligent software capabilities designed for enterprise networking environments.
▪ High-density Ethernet ports supporting large-scale access aggregation
▪ Flexible uplink interfaces enabling high-speed backbone connectivity
▪ Advanced Layer 2 and Layer 3 switching capabilities
▪ Intelligent traffic scheduling for optimized bandwidth utilization
▪ Enhanced security policies for enterprise data protection
▪ Energy-efficient design for reduced operational cost
▪ Support for cloud-based network management systems
The technical foundation of the S5735-S48S4XE-V2 ensures stable, high-capacity performance for demanding enterprise environments.
▪ Ports: 48 x Gigabit Ethernet downlink ports and 4 x 10GE SFP+ uplink ports
▪ Switching Capacity: High backplane capacity designed for non-blocking performance
▪ Forwarding Rate: Multi-million packets per second forwarding capability
▪ Uplink Interfaces: 10GE optical ports supporting high-speed backbone integration
▪ Power Supply: Redundant power support for high availability scenarios
▪ Cooling System: Intelligent fan system for adaptive thermal control
▪ MAC Address Table: Large-scale MAC learning for enterprise deployments
▪ VLAN Support: Extensive VLAN segmentation for network isolation
The hardware architecture of the S5735-S48S4XE-V2 is optimized for reliability and scalability. It integrates high-performance forwarding chips that ensure efficient packet processing even under heavy traffic loads.
The internal design includes modular airflow channels and redundant components, reducing the risk of downtime in mission-critical environments. This architecture allows the switch to maintain stable performance even in high-density deployment scenarios.
The forwarding engine is built to handle high-speed data transmission with minimal latency. It ensures that packets are processed efficiently across all ports, making it suitable for latency-sensitive applications such as video conferencing and cloud computing.
The device incorporates smart cooling and energy-efficient power modules. These features dynamically adjust power consumption based on workload, ensuring optimal performance while reducing energy costs.
The S5735-S48S4XE-V2 provides a high-density port configuration designed for aggregation and enterprise backbone roles. Its combination of copper and fiber interfaces enables flexible deployment in different network topologies.
It supports advanced switching mechanisms such as MAC-based forwarding, VLAN segmentation, and traffic prioritization, ensuring efficient utilization of network resources.
The Layer 2 capabilities include MAC address learning, spanning tree protocols, and VLAN trunking. These features ensure loop-free and stable network communication across large campus environments.
The switch also supports basic Layer 3 routing functions, enabling inter-VLAN routing and improved network segmentation. This reduces dependency on external routing devices and simplifies network architecture.
The S5735-S48S4XE-V2 is built for high throughput environments, ensuring consistent performance under heavy workloads. It can handle simultaneous traffic flows without packet loss, making it ideal for enterprise-level applications.
Its high forwarding rate ensures smooth data transmission across large networks, while intelligent load balancing optimizes traffic distribution.
Security is a core component of the S5735-S48S4XE-V2 design. It integrates multiple layers of protection to safeguard enterprise networks from unauthorized access and attacks.
▪ Access control lists (ACLs) for traffic filtering
▪ DHCP snooping to prevent rogue server attacks
▪ ARP inspection for spoofing prevention
▪ Port security to restrict unauthorized device access
▪ Network isolation through VLAN segmentation
The S5735-S48S4XE-V2 supports centralized and cloud-based network management, allowing administrators to monitor performance and configure devices remotely. This reduces operational complexity and improves troubleshooting efficiency.
It also provides real-time diagnostics and performance analytics, helping IT teams proactively identify and resolve network issues before they impact users.
Cloud integration enables remote configuration, firmware updates, and network optimization. This is especially beneficial for distributed enterprise environments with multiple branch locations.
The switch includes monitoring tools that provide visibility into bandwidth usage, error rates, and device health. These insights help maintain optimal network performance.
The S5735-S48S4XE-V2 is versatile and can be deployed in various enterprise scenarios. It is commonly used in campus aggregation layers, enterprise backbones, and data center access networks.
Its scalability makes it suitable for both medium and large organizations that require stable and high-speed connectivity across multiple departments or buildings.
In campus environments, the switch acts as a central aggregation device, connecting multiple access switches and routing traffic efficiently between users, servers, and external networks.
It supports high-bandwidth applications such as video streaming, VoIP communication, and cloud-based learning systems in educational institutions.
The S5735-S48S4XE-V2 offers several advantages that make it a strong choice for enterprise networking infrastructure.
▪ High scalability for growing network demands
▪ Reliable performance under heavy traffic conditions
▪ Strong security mechanisms for data protection
▪ Energy-efficient operation for reduced costs
▪ Flexible deployment in multiple network layers
The S5735-S48S4XE-V2 is positioned as a mid-to-high-end enterprise switch designed for aggregation and core access roles. It bridges the gap between access-layer simplicity and core-layer performance, offering a balanced solution for enterprise networks.
Compared to entry-level switches, it provides significantly higher throughput, better redundancy options, and more advanced security features, making it suitable for mission-critical environments.
The switch is designed with long-term reliability in mind. Its redundant components and intelligent diagnostics reduce downtime and maintenance costs.
Routine maintenance is simplified through centralized management tools, allowing IT teams to perform updates and monitoring without disrupting network operations.
The S5735-S48S4XE-V2 is a powerful enterprise switch that delivers a combination of high performance, scalability, and security. Its robust hardware design and intelligent software features make it ideal for modern campus and enterprise networks.
With advanced switching capabilities, flexible deployment options, and strong network management support, it stands as a reliable solution for organizations aiming to build efficient and future-ready network infrastructures.
Huawei All Series Switches New and Used
For Huawei product list and quote, please visit: https://www.hi-network.com/categories/huawei or contact us at www.hi-network.com (Email: info@hi-network.com)
| Item | Details |
|---|---|
| Description | S5735-S48S4XE-V2 (48*GE SFP ports, 4*10GE SFP+ ports, 2*12GE stack ports, without power module) |
| Part Number | 98012232 |
| Model | S5735-S48S4XE-V2 |
| First supported version | V600R023C00 |
| Remarks |
|
1 | Forty-eight 100/1000BASE-X ports | 2 | Four 10GE SFP+ ports |
3 | Two stack ports | 4 | One console port |
5 | One USB port | 6 | One ETH management port |
7 | One PNP button NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 8 | Ground screw NOTE: It is used with a ground cable. |
9 | Power module slot 1 NOTE: Applicable power modules:
When 1000BASE-X Ethernet optical ports use 25 or more GE optical modules with a distance of 40 km or longer, a power module with a minimum power of 180 W is required. | 10 | Power module slot 2 NOTE: Applicable power modules:
When 1000BASE-X Ethernet optical ports use 25 or more GE optical modules with a distance of 40 km or longer, a power module with a minimum power of 180 W is required. |
| Port | Connector Type | Description | Available Components |
|---|---|---|---|
| 100/1000BASE-X port | SFP | A 100/1000BASE-X port can send and receive data at 100/1000 Mbit/s. |
|
| 10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
| Stack port | SFP+ | A stack port connects multiple switches through stack cables and virtualize them into one switch logically. It is used only in stacking scenarios and does not need to be configured. In a stack, the working rate of a single port is increased to 12 Gbit/s by default when using the 0.5 m or 1.5 m SFP+ dedicated stack cables, and the working rate of a single port is 10 Gbit/s when using the 3 m SFP+ dedicated stack cables. |
|
| Console port | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
| ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | Ethernet cable |
| USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. | USB flash drive |
No. | Indicator | Name | Color | Status | Description |
|---|---|---|---|---|---|
1 | PWR | Power module indicator | - | Off | The switch is powered off. |
Green | Steady on | The power supply is normal. | |||
Yellow | Steady on | The switch has multiple power modules installed. Any of the following situations occurs in a power module slot:
| |||
2 | SYS | System status indicator | - | Off | The system is not running. |
Green | Fast blinking | The system is starting. | |||
Green | Steady on | During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. | |||
Green | Slow blinking | The system is running normally. | |||
Red | Steady on | The system does not work normally after registration, or alarms such as fan module, power module, optical module, or temperature alarms are generated. | |||
3 | MST | Stack indicator | - | Off | The switch is not the master switch in a stack. |
Green | Blinking | The switch is the master switch in a stack or a standalone switch. | |||
4 | ID | ID indicator | - | Off | The ID indicator is not used (default state). |
Blue | Steady on | The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. | |||
5 | - | Service port indicator (two indicators for each port) NOTE: Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green). Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. | Meanings of service port indicators vary in different modes. For details, see Table 4-691. NOTE: If a power failure occurs on a device's PCB board, indicators of the last four GE, 10GE, or 25GE optical ports on the device's front panel blink green cyclically at an interval of 1 second, with each indicator illuminating for 0.25 seconds. | ||
6 | L/A | ETH port indicator | - | Off | The ETH port is not connected. |
Green | Steady on | The ETH port is connected. | |||
Green | Blinking | The ETH port is sending or receiving data. | |||
7 | USB | USB-based deployment indicator | - | Off | No USB flash drive is installed, or the indicator fails. |
Green | Steady on | USB-based deployment succeeds. If there is no deployment configuration file, deployment will be repeatedly performed. In this case, the indicator is also steady green. | |||
Green | Blinking | USB-based deployment is in progress. | |||
Red | Steady on | USB-based deployment fails. | |||
Display Mode | Color | Status | Description |
|---|---|---|---|
Default mode (LINK indicator) | - | Off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | |
Default mode (ACT indicator) | - | Off | The port is not connected or has been shut down, or no data is transmitted or received. |
Yellow | Blinking | The port is sending or receiving data. | |
Speed mode (LINK indicator) NOTE: In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode speed diagnostic command. The default mode is automatically restored after 45s. | - | Off | The port is not connected or has been shut down. |
Green | Steady on |
| |
Green | Blinking |
|
The switch can use a single power module or two power modules for 1+1 power redundancy. The power modules with fans and power modules without fans cannot be installed on the same switch.
The switch has two built-in fans for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
| Item | Specification |
|---|---|
| Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] | 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
| Chassis height [U] | 1 U |
| Chassis material | Metal |
| Weight without packaging [kg(lb)] | 5.2 kg (11.46 lb) |
| Weight with packaging [kg(lb)] | 7.1 kg (15.65 lb) |
| Typical power consumption [W] | 72.3 W |
| Typical heat dissipation [BTU/hour] | 246.69 BTU/hour |
| Maximum power consumption [W] |
|
| Maximum heat dissipation [BTU/hour] |
|
| Static power consumption [W] | 31.5 W |
| MTBF [years] | 78.95 years |
| Availability | > 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] | 43.8 dB(A) |
| Noise at normal temperature (acoustic pressure) [dB(A)] | 31.80 dB(A) |
| Number of card slots | 0 |
| Number of power slots | 2 |
| Number of fans modules | 2 |
| Redundant power supply | 1+1 Power modules without fans and power modules with fans cannot be installed in the same chassis. |
| Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
| Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
| Power supply mode | Pluggable power supply |
| Rated input voltage [V] |
|
| Input voltage range [V] |
|
| Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
| Memory | 2 GB |
| Flash memory | Physical space: 1 GB |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| USB | Supported |
| RTC | Not supported |
| RPS input | Not supported |
| Power supply surge protection [kV] |
|
| Ingress protection level (dustproof/waterproof) | IP20 |
| Types of fans | Built-in |
| Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
| Airflow direction | Air intake from left, front, and right and air exhaust from rear |
| PoE | Not supported |
| Certification | EMC certification Safety certification Manufacturing certification |
Hot Tags :
Huawei Switches
hot products