Register now for better personalized quote!
ASR-9006-DC-V2
  • ASR-9006-DC-V2

Sealed New ASR-9006-DC-V2 Cisco Router ASR 9006

5688 $13599.00 (58.2% OFF)
Detail: Cisco ASR 9006 System ASR-9006-DC-V2 ASR 9006 DC Chassis with PEM Version 2
Model: ASR-9006-DC-V2
Condition: Factory Sealed New, In stock
Related:
Warranty:
1 Year-Warranty
100% Money-back
Free After-Sales Service
Shipping:
Air Shipping to United States
, Most Customers Receive during 5-7 Days
?
If you finish the payment today,
your order will arrive within the
estimated delivery time.
Ships to:
25
2-7 Days US$
Payment:
  • Pay by wire transfer.
  • Pay with your paypal.
  • Pay with your Visa credit card.
  • Pay with your Mastercard credit card.
  • Pay with your Discover Card.
  • Pay by Western Union.
More
Quantity
- +
add to Cart quick quote
add to Cart quick quote
  • Description
  • Specification
  • Reviews
  • Q&A
  • Warranty
  • Download

Sealed New ASR-9006-DC-V2 Cisco Router ASR 9006


(Note: Cisco discount and Stock always changed, we will try most effort to follow it but can not ensure every web was changed accordingly. So Our Products Service will contact you after order if meet such special condition.)


ASR-9006-DC-V2 is the Cisco ASR-9006 DC Chassis with PEM Version 2. The Cisco ASR 9000 Series has a modular power architecture available in both AC and DC. The power supplies are housed in field-serviceable Power Entry Modules (PEMs), which also come in AC and DC forms. Each PEM can hold up to three or four modules depending on its corresponding type, with no power zones or placement restrictions (mixing of AC and DC supplies is not supported).
To provide ASR 9006 functions, ASR-9006-DC-V2 needs to be configured with necessary components separately.


Quick Specification


Product Code

ASR-9006-DC-V2

Type

Cisco ASR-9006 DC Chassis with PEM Version 2

Slots

4 Line Cards

2 RSPs

Rack Size

10 RU

Max Capacity

7 Tbps

Size (H x W x D)

17.5 in. x 17.5 in. x 28.65 in.

Power

AC: 3 kW power module
DC: 1.5 kW or 2.1 kW power modules
Note: Mixing of AC and DC modules is not supported

Fan

2 fan trays

Airflow

Side to Side (Front to Back Option)

RSP / RP

2 (1+1 RSP redundancy)

Fabric Architecture

1+1 fabric redundancy

Software

IOS XR



Product Details


The Front Panel

asr-9006-dc-v2-datasheet



Accessories For ASR-9006-DC-V2


Recommended Components:


Model

Description

ASR-9006-FAN

ASR-9006-FAN Cisco ASR 9006 Series Fan Tray

PWR-2KW-DC-V2

Cisco ASR 9000 Power Module PWR-2KW-DC-V2 2KW DC Power Module Version 2 for ASR-9006 & ASR-9010 Spare

A9K-RSP440-TR

Cisco ASR 9000 Route Switch Processor A9K-RSP440-TR ASR9K Route Switch Processor with 440G/slot Fabric and 6GB

A9K-RSP440-SE

Cisco ASR 9000 Route Switch Processor A9K-RSP440-SE ASR9K Route Switch Processor with 440G/slot Fabric and 12GB

A9K-SIP-700

Cisco ASR 9000 Interface A9K-SIP-700 Cisco ASR 9000 Series SPA Interface Processor-700

A9K-24X10GE-SE

Cisco ASR 9000 Series Router Ethernet Linecard A9K-24X10GE-SE ASR 9000 24-port 10GE, Service Edge Optimized LC (spare)

A9K-2X100GE-SE

Cisco ASR 9000 Series Router Ethernet Linecard A9K-2X100GE-SE ASR 9000 2-port 100GE, Service Edge Optimized LC (spare)

A9K-2X100GE-TR

Cisco ASR 9000 Series Router Ethernet Linecard A9K-2X100GE-TR ASR 9000 2-port 100GE, Packet Transport Optimized LC (spare)


Compare To Similar Items


Model

ASR-9006-DC

ASR-9006-DC-V2

Type

Cisco ASR-9006 DC Chassis

Cisco ASR-9006 DC Chassis PEM Version 2

Slots

4 Line Cards

2 RSPs

4 Line Cards

2 RSPs

Rack Size

10 RU

10 RU


Get More Information

Do you have any question about the ASR-9006-DC-V2?

Contact us now via [email protected].

Specific Data Sheet:


Product Name

ASR-9006-DC-V2

Description

Cisco ASR 9006 System ASR-9006-DC-V2 ASR 9006 DC Chassis with PEM Version 2

Physical specifications

Height: 17.50 in. (444.5 mm) (10 RU)

Width: 17.38 in. (441.45 mm)

Depth:

●  With doors: 29.05 in. (737.9 mm)

●  Without doors: 29.05 in. (737.9 mm)

Weight:

●  89.55 lb (40.7 kg) (chassis with PEM)

150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 FAN trays, PEMs

Slot orientation

Horizontal

Cisco ASR 9000 Series RSP

Dual redundant RSPs with integrated fabric in 2 slots

Cisco ASR 9000 Series line cards

4 line-card slots

“Commons” components

2 RSPs

2 fan trays

1 PEM (either DC or AC)

1 fan filter

Reliability and availability

Fabric redundancy

Fan redundancy

Feed redundancy

Power-supply redundancy

RSP redundancy

Software redundancy

Rack mounting

19-in. default

21- and 23-in. adapters available

Note: Minimum 17.75-in. opening between posts is needed for proper operation

Cabinet mounting

Yes

Note: Doors not recommended in enclosed cabinets

Wall mounting

No

Airflow

Right-to-back, Front-to-back with baffle

Performance

Fabric

One per RSP:

●  Active/active nonblocking operation mode in dual-RSP redundant configuration

●  Fully redundant in dual-RSP redundant configuration

●  Built-in service-intelligence and traffic-prioritization capability

Thermal

Two fan trays:

●  6 high-efficiency fans per tray

●  Variable-speed fans for optimal thermal performance

●  No single point of failure

Fabric

One per RSP:

●  Active/active nonblocking operation mode in dual-RSP redundant configuration

●  Fully redundant in dual-RSP redundant configuration

●  Built-in service-intelligence and traffic-prioritization capability

Power

Modularity

Pay-as-you-grow power for future scalability, available in AC and DC.

Multiple power module types:

●  3 kW AC power module

●  2.1 kW DC power module

Note: Mixing of AC and DC modules is not supported

Redundancy

●  AC: N+N redundancy

●  DC: N+1 redundancy

●  Power module redundancy

●  A/B Feed redundancy

Power zones

No power zone restrictions

Fully load-sharing power infrastructure

Power input

Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)

Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)

Power-module airflow

Front-to-back

Operating temperature (nominal)

41 to 104ºF (5 to 40ºC)

Operating temperature (short-term)

ASR 9006: 23 to 131ºF (-5 to 55ºC)

ASR 9010: 23 to 122ºF (-5 to 50ºC)

Operating humidity (nominal) (relative humidity)

5 to 90%

Storage temperature

-40 to 158ºF (-40 to 70ºC)

Storage (relative humidity)

5 to 93%

Operating altitude

-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)

Network Equipment Building Standards (NEBS)

Cisco ASR 9006 is designed to meet:

●  SR-3580: NEBS Criteria Levels (Level 3)

●  GR-1089-CORE: NEBS EMC and Safety

●  GR-63-CORE: NEBS Physical Protection

●  VZ.TPR.9205: Verizon TEEER

ETSI standards

Cisco ASR 9006 is designed to meet:

●  EN300 386: Telecommunications Network Equipment (EMC)

●  ETSI 300 019 Storage Class 1.1

●  ETSI 300 019 Transportation Class 2.3

●  ETSI 300 019 Stationary Use Class 3.1

EMC standards emission

Cisco ASR 9006 is designed to meet:

●  FCC Class 47CFR15 A

●  ICES 003 Class A

●  AS/NZS CISRP22 Class A

●  CISPR 22 (EN55022) Class A

●  VCCI Class A

●  BSMI Class A

●  IEC/EN 61000-3-12: Power Line Harmonics

●  IEC/EN 61000-3-11: Voltage Fluctuations and Flicker

●  EN55022: Information Technology Equipment (Emissions)

●  EN 50121-4: Railway EMC

EMC standards immunity

Cisco ASR 9006 is designed to meet:

●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)

●  IEC/EN-61000-4-3: Radiated Immunity (10V/m)

●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)

●  IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)

●  IEC/EN-61000-4-5: Signal Surge Ports (1kV)

●  IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)

●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)

●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)

●  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations

●  EN55024: Information Technology Equipment (Immunity)

●  EN50082-1/EN-61000-6-1: Generic Immunity Standard

●  EN 50121-4: Railway EMC

Safety

Cisco ASR 9006 is designed to meet:

●  UL/CSA/IEC/EN 60950-1

●  IEC/EN 60825 Laser Safety

●  ACA TS001

●  AS/NZS 60950

●  FDA Code of Federal Regulations Laser Safety


Customer Reviews

Do you have other questions or feedback? You may write here:

*Question:
*Use your name:
*Email:

What is Guaranteed.

After receiving your order, take a full month to try it out. If you find quality is not good , we'll take it back and refund your money. Your complete satisfaction is GUARANTEED or your money back. That's guaranteed.


After your order items which are available. We will use most fast delivery way to global countries. Normally we will ship out cargos during 3 -5 days. And international delivery will take about 3- 10 days according to your location.


Service Never Ends.

Hardwares Warrany Time:

Original New Sealed Hardware: 3 Years
Refurbished/Used Original Devices: 1 Year

After warranty time, you also can contact us to return back for repair service. Everything you purchase from HI-NETWORK.COM. We will offer lifetime online service support for your any possible questions. 


Resources Downloads

Support and Resources

Related Products

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.